DBO Preanalytical Systems
DBO gamma sterile blood collection tubes

Sterile inside.
Every tube.

Each tube is gamma-irradiated with Cobalt-60 after it is sealed and packed. The rays pass through the carton, stopper and wall, so the inside stays sterile until the moment of collection.

Sterility assurance
10−6
Minimum dose
25 kGy
Chemical residue
None
GERMS PER TUBE 100 0.0 kGy IRRADIATING

Every 3 kGy of gamma dose removes 9 in 10 remaining germs. At 25 kGy the chance of a single survivor is below one in a million.

The dose journey

From a hundred germs to one in a million.

Radiation removes germs in steps. Every 3 kGy, nine out of ten survivors are gone. Scroll to raise the dose.

ABSORBED DOSE
0.0kGy
SURVIVORS PER TUBE
100
0 KGY · BEFORE

A clean tube still carries life.

Even with careful manufacturing, a tube can hold a few germs from the environment. Here we assume 100.

3 KGY · ONE STEP

Nine in ten are gone.

Gamma rays break the germs' DNA, so they cannot grow.

6 KGY · TWO STEPS

One survivor left.

On average one germ remains. Not good enough to call the tube sterile.

15 KGY · FIVE STEPS

Too few to count.

Now the question is how many tubes you would need to check to find a single survivor. About a thousand.

25 KGY · STERILE

One in a million, or better.

At the validated dose, the chance of any germ surviving is below one in a million. That is what the STERILE R symbol on every DBO label means.

48 hours later

Same blood. Different tube.

Plate the inside of a non-sterile tube and a DBO tube, then incubate. In a blood culture, anything that grows is reported as the patient's infection.

Non-sterile tube

Looks clean.

Nothing visible before incubation.

DBO gamma sterile

Sterile inside.

Probability of a surviving germ below 10⁻⁶.

00 h at 35 °C
Why it matters

Sterility protects the result, and the patient.

Four reasons laboratories choose gamma sterile tubes.

01 · Blood culture

Fewer false-positive cultures.

Germs that arrive with the tube can grow and be read as bloodstream infection. That means repeat draws, unnecessary antibiotics and longer hospital stays.

02 · Patient safety

Safe if blood flows back.

In a vacuum system, blood can briefly flow back toward the vein. A sterile inside removes that route.

03 · Molecular testing

Cleaner PCR.

Less risk of microbial DNA entering samples for PCR, viral load and sequencing.

04 · Chemistry

No chemical residue.

Gamma adds nothing to the tube. Gas sterilization with ethylene oxide leaves residues that must be tested.

Methods compared

Gamma vs. gas.

Why gamma suits evacuated tubes better than ethylene oxide.

Gamma · Co-60
Ethylene oxide
Non-sterile
Works through sealed pack
Yes
Gas must seep in
No
Chemical residue
None
Must be tested
—
Effect on vacuum
None
Pressure cycles
None
Ready to ship
Immediately
After airing out
Immediately
Sterility claim
10⁻⁶
10⁻⁶
None
For your audit file

Every lot is on record.

Enter the lot number from any DBO label to see its Certificate of Analysis.