Sterile inside.
Every tube.
Each tube is gamma-irradiated with Cobalt-60 after it is sealed and packed. The rays pass through the carton, stopper and wall, so the inside stays sterile until the moment of collection.
- Sterility assurance
- 10−6
- Minimum dose
- 25 kGy
- Chemical residue
- None
Every 3 kGy of gamma dose removes 9 in 10 remaining germs. At 25 kGy the chance of a single survivor is below one in a million.
What do you need to do today?
Every free DBO tool, grouped by task. Or press / to search.
At the bench, in ten seconds.
The questions phlebotomists and lab staff ask most, answered from CLSI, EFLM, WHO and ADA guidance. Follow your tube's IFU and local policy where they differ.
Latest from the blog and tech insights.
From a hundred germs to one in a million.
Radiation removes germs in steps. Every 3 kGy, nine out of ten survivors are gone. Scroll to raise the dose.
A clean tube still carries life.
Even with careful manufacturing, a tube can hold a few germs from the environment. Here we assume 100.
Nine in ten are gone.
Gamma rays break the germs' DNA, so they cannot grow.
One survivor left.
On average one germ remains. Not good enough to call the tube sterile.
Too few to count.
Now the question is how many tubes you would need to check to find a single survivor. About a thousand.
One in a million, or better.
At the validated dose, the chance of any germ surviving is below one in a million. That is what the STERILE R symbol on every DBO label means.
Same blood. Different tube.
Plate the inside of a non-sterile tube and a DBO tube, then incubate. In a blood culture, anything that grows is reported as the patient's infection.
Looks clean.
Nothing visible before incubation.
Sterile inside.
Probability of a surviving germ below 10⁻⁶.
Sterility protects the result, and the patient.
Four reasons laboratories choose gamma sterile tubes.
Fewer false-positive cultures.
Germs that arrive with the tube can grow and be read as bloodstream infection. That means repeat draws, unnecessary antibiotics and longer hospital stays.
Safe if blood flows back.
In a vacuum system, blood can briefly flow back toward the vein. A sterile inside removes that route.
Cleaner PCR.
Less risk of microbial DNA entering samples for PCR, viral load and sequencing.
No chemical residue.
Gamma adds nothing to the tube. Gas sterilization with ethylene oxide leaves residues that must be tested.
Gamma vs. gas.
Why gamma suits evacuated tubes better than ethylene oxide.
Every lot is on record.
Enter the lot number from any DBO label to see its Certificate of Analysis.
Certificate of Quality
Every DBO lot is released with a Certificate of Quality approved by our Quality Assurance department. Enter the lot number to view, print or download it.
- Issued
- For each production lot
- Approved by
- Quality Assurance
- Sterility
- SAL 10−6, gamma irradiation
- Standards
- ISO 6710 · ISO 11137 · ISO 13485
About the certificate
What the certificate confirms
- Product reference, lot, manufacturing and expiry dates
- Visual, physical, chemical and microbial inspection results
- Sterility assurance level of 10−6
- Conformity with ISO 6710, EN 14820, ISO 11137, ISO 13485, ISO 9001 and Directive 98/79/EC
Validity
Each certificate applies only to the lot stated on it. Keep the PDF with your goods-receipt or audit records.
Other documents
For instructions for use, declarations of conformity, white papers, clinical validation and instrument compatibility, contact the technical team.
technical@drbloodo.com →Everything for your files, in one place.
IFUs, clinical validation, white papers and declarations by request; the full product range below. Technical team: technical@drbloodo.com.
Get the documents you need.
Tick what you need and fill in a few details. We write the email for you; copy it and send it to the address shown.
technical@drbloodo.comThe full DBO range, searchable.
Evacuated PHLECOCUUM tubes, SCHRAUBE SAMMLUNG screw-cap tubes and SCHRAUBE MINI micro tubes. Quote the product code when you request documents.
| Cap | Code | Product | Line | Additive | Volume |
|---|
The rules we follow.
Tap a standard to see, in one line, what it covers.
Does gamma harm the tube?
No. Every part is tested after irradiation. Tap a part to see what we check.
Plastic tube (PET)
Rubber stopper
Separator gel
Clot activator
EDTA, citrate and fluoride
Heparin
Where the radiation comes from.
Cobalt-60 is a radioactive metal sealed inside steel rods. It gives off gamma rays: invisible, high-energy rays that pass straight through packaging.
Does every tube get enough?
Rays weaken as they travel through a carton, so the middle gets less than the sides. We irradiate from both sides and measure. Every tube must get at least 25 kGy, and no tube more than the limit. Try it.
Doses in kGy. Spread = highest ÷ lowest. Target: lowest ≥ 25, highest ≤ 45 (example limit).
How much dose makes a tube sterile?
Each step of dose removes 9 out of 10 remaining germs. "Sterile" means the chance of even one germ surviving is below one in a million (10⁻⁶). Move the sliders.
Simplified model for learning. Real dose setting follows ISO 11137-2 with tests on actual product.
Better samples start at the vein.
20 short, hands-on courses on venous and capillary collection, sample quality and safety, built on CLSI, WHO and EFLM guidance. Every course has learning objectives, a simulation and a knowledge check. Pass the final assessment to earn your certificate.
Courses
Every DBO tube type, in order of draw.
Tap a tube type to see its additive, use, inversions and every size we make, with product codes. The numbers show the order of draw.
Cap colours follow common practice; always confirm against the tube label and IFU.
An unexpected result? Trace it back.
Pick what the laboratory reported. See the collection and handling causes to check, most likely first.
The numbers to remember.
Release as soon as blood flows into the first tube.
Bevel up. 21–22G for most adult veins.
Clot-activator tubes, upright, before centrifuging.
Of the nominal volume, to keep the 1:9 ratio.
Spin serum and plasma within 2 hours of collection.
Stated by the patient, matched to wristband and form.
Train your whole team with us.
Our application specialists run on-site sessions, and the Academy courses are available as packages for your hospital's learning system.
Hands-on workshop
Venipuncture practice on training arms, order of draw, and your own analyser's sample requirements. 2–3 hours, up to 20 staff.
Learning system package
The Academy courses as SCORM packages, so you can assign and track them in your hospital's own learning system.
Wall charts and cards
Order-of-draw posters and pocket reference cards for collection rooms and wards.
technical@drbloodo.comPre-analytical quality suite
Measure, standardise and prove the quality of your samples before they reach the analyser. Free tools aligned with ISO 15189:2022, CLSI and EFLM.
- Measure
- Self-check, self-audit and anonymous peer benchmark
- Standardise
- Centrifuge settings, SOP generator, bench posters
- Prove
- Evaluate DBO on your own analysers
How good is your preanalytical quality?
Enter one month of sample rejections to see your error rates and Sigma scores, the cost of recollections, and where to act first.
Figures stay in your browser; nothing is sent unless you choose to share the report.
Enter the number of samples received and the rejections by cause to see your error rates, Sigma scores and recommended actions.
Sigma is calculated from the defect rate (defects per million, with the conventional 1.5 shift). As a rule of thumb, 4 Sigma or more is good practice, 3–4 is acceptable, and below 3 calls for action.
Find the gaps before your assessor does.
28 questions on requests, collection, staff, tubes, transport, receipt, processing and analysers, mapped to the pre-examination clauses of ISO 15189:2022. You get a score for each area and an action plan with the DBO poster, course or tool that helps.
Answers stay in this browser until you print or share the report. This is a self-assessment to help you prepare and does not replace an accreditation assessment.
The right rpm, on every lid.
Centrifuges are set in rpm, but tubes need a g-force. Enter each centrifuge's rotor radius once, and print a sticker showing the rpm and time for every DBO tube type.
Your collection SOP, drafted in minutes.
Answer a few questions and get a sample collection and handling SOP aligned with ISO 15189:2022, with your DBO tubes, order of draw and centrifuge settings filled in. Download it for Word or print it.
Prove the switch on your own analysers.
A side-by-side comparison of DBO tubes with your current tubes, following the approach of CLSI GP34. Enter your paired results and get a verification report for your records and accreditation file.
- 01PlanChoose the analytes to compare and set the allowable bias for each from your laboratory's quality specifications.
- 02CollectFrom each volunteer or patient, fill one current tube and one DBO tube of the same type in the same venipuncture. Alternate which tube is filled first.
- 03ProcessHandle both tubes identically: same clotting time, centrifugation, storage and the same analytical run.
- 04CompareUse at least 20 pairs per analyte, ideally 40, covering low, normal and high values. Paste the pairs below.
Statistics: mean difference (DBO − current) with its 95% confidence interval, percentage bias, Bland–Altman limits of agreement and correlation. An analyte meets the criterion when the whole 95% confidence interval of the percentage bias lies within your allowable bias. Your data stays in your browser.
Print the rules for the bench.
Ten A4 posters for the collection room, sample processing and the analyser room. Tap a poster to see it full size, then print it or the whole set.
Insights for people who draw blood
Evidence-based guides for phlebotomists, nurses and laboratory professionals. Every article cites the guidelines it relies on and links to a free tool you can use straight away.
- Articles
- —
- Topics
- —
- Every article
- Cites CLSI, EFLM, WHO or IFCC sources
- Last updated
- —
All articles
One email when we publish. Nothing else.
Share what works at your bench.
We welcome articles and clinical review from pathologists, laboratory scientists, phlebotomy leads and nurse educators. Authors and reviewers are named with their credentials on every article.
Propose an article →