Tech insight · Quality

Pre-analytical quality indicators: what to measure and how to benchmark

Most lab errors happen before analysis. The IFCC pre-analytical quality indicators to track, how to calculate them, and how to benchmark against peers.

By DBO Technical and Scientific TeamChecked against the guidelines cited below on 25 October 2026Published 25 October 2026 · 3 min read
WhatsAppLinkedInEmail

You cannot improve what you do not measure. A laboratory that knows its haemolysis rate by ward, its rate of clotted EDTA samples and its misidentification rate can target training where it changes outcomes. One that does not is left reacting to individual complaints.

Why the pre-analytical phase

Studies over three decades have found that most errors in the total testing process happen before analysis: in the request, identification, collection, transport and processing of samples. Analytical errors have fallen dramatically with automation and quality control; pre-analytical errors depend on people, in many places, often outside the laboratory's direct control.

The IFCC model of quality indicators

The IFCC WG-LEPS has developed a model of quality indicators (MQI) used by laboratories around the world. Each indicator is a percentage with a defined numerator and denominator. Performance specifications at three levels (high, medium and low) are set from the results of participating laboratories and updated periodically.

Core pre-analytical indicators include:

IndicatorCalculation
Misidentified samplesMisidentified samples ÷ total samples
Wrong containerSamples in the wrong container ÷ total samples
Insufficient volumeSamples with insufficient volume ÷ total samples
Haemolysed samplesHaemolysed samples (by haemolysis index) ÷ total chemistry samples
Clotted samplesClotted samples ÷ total samples with anticoagulant
Inappropriate sample-to-anticoagulant ratioSamples with the wrong ratio ÷ total samples with anticoagulant
Transport problemsSamples damaged, lost or delayed in transport ÷ total samples

Making the numbers trustworthy

  1. Define each indicator in your quality manual, with numerator, denominator and data source, and do not change it without recording why.
  2. Use objective criteria: the analyser's haemolysis index rather than visual inspection; a documented definition of a clotted sample.
  3. Collect monthly and keep at least a year's history.
  4. Break down by location: emergency department, wards, outpatients, external collection centres.
  5. Set a target using published specifications, and an action limit that triggers investigation.
  6. Review at management review, as ISO 15189 requires, and record actions and their effect.

Benchmarking with peers

An indicator means most when you know how others perform. Programmes such as the IFCC MQI and national external quality assessment schemes publish percentile results by peer group. Comparing with laboratories of similar size and patient mix avoids the unfair comparison of a trauma centre with an outpatient clinic.

DBO's free pre-analytical benchmark lets a laboratory enter its monthly indicators anonymously and see where it sits against peers of the same size band and type, with an IFCC reference column. No patient data is collected, groups with fewer than 11 laboratories are not shown, and your laboratory can delete its data at any time.

References

  1. Sciacovelli L, Padoan A, Aita A, Basso D, Plebani M. Quality indicators in laboratory medicine: state-of-the-art, quality specifications and future strategies. Clin Chem Lab Med. 2023;61(4):688–695.
  2. ISO 15189:2022. Medical laboratories: requirements for quality and competence. International Organization for Standardization; 2022.
  3. Plebani M. Errors in clinical laboratories or errors in laboratory medicine? Clin Chem Lab Med. 2006;44(6):750–759.
  4. Lippi G, Plebani M, Di Somma S, Cervellin G. Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories. Crit Rev Clin Lab Sci. 2011;48(3):143–153.
Free DBO toolBenchmark your laboratory anonymously

Read next

New articles by email

One short email when we publish something new. No other mailings. Unsubscribe with one click.