Haemolysis at collection: the common causes and how to cut your rate
Haemolysis is the top reason samples are rejected. The collection and handling causes, which results it changes, and a plan to measure and cut your rate.
Haemolysis, the rupture of red cells with release of their contents into serum or plasma, is the most common reason a laboratory rejects or flags a sample. In emergency departments the rate can be several times higher than in outpatient clinics. Each haemolysed sample means a repeat needle for the patient and a delay in treatment.
The good news is that almost all of it is created after the blood leaves the vein, which means it can be prevented.
In vivo or in vitro?
In vivo haemolysis happens inside the patient: haemolytic anaemias, transfusion reactions, mechanical heart valves, severe infections. It is a clinical finding and must be reported, not rejected.
In vitro haemolysis happens during or after collection. It accounts for the great majority of haemolysed samples, and it is the laboratory's and the collector's problem to fix.
If several consecutive samples from a patient are haemolysed despite good technique, tell the laboratory. It may be in vivo, and that matters for the patient.
Collection causes
| Cause | Why it haemolyses | What to do |
|---|---|---|
| Drawing through an IV catheter | Turbulent flow through narrow plastic, often with a syringe | Draw by venepuncture where possible. If a line must be used, follow your local line-draw procedure |
| Difficult or prolonged draw | Repeated probing, slow trickling flow | Choose the vein carefully; if it fails, stop and re-site |
| Very small needle | High shear as blood is pulled through | Use 21G for routine adults; 22G or 23G for small, fragile veins |
| Syringe transfer | Forcing blood through the needle or pulling the plunger hard | Use a safety transfer device; let the vacuum draw the blood |
| Wet alcohol | Alcohol entering the sample | Let the site dry fully |
| Tourniquet too long | Stasis and fragile cells | One minute maximum; release when blood flows |
| Underfilled tube | Excess vacuum pulls blood through hard; wrong additive ratio | Let each tube fill until the vacuum is exhausted |
| Shaking the tube | Mechanical damage | Gentle, full inversions only |
Handling and transport causes
- Pneumatic tube systems with high speeds and sharp turns. Ask your engineers for acceleration data and test with paired samples.
- Temperature extremes: freezing whole blood, or leaving tubes on a hot dashboard.
- Delayed separation of serum or plasma from cells, especially in the heat.
- Re-centrifuging gel tubes after the barrier has formed.
- Centrifuge settings far above the IFU, or a failing brake.
Which results change
Red cells contain far more potassium, LDH, AST and phosphate than plasma, so even slight haemolysis raises them. Free haemoglobin also interferes optically with many photometric methods, and enzymes released from cells interfere with some immunoassays. Insulin and troponin results can also be affected depending on the method.
Each method has its own tolerance. The analyser's haemolysis index, together with the manufacturer's interference limits, is the only reliable way to decide whether a result can be released. Visual inspection misses low levels and over-calls others.
A practical reduction plan
- Measure. Use the haemolysis index on every chemistry sample. Calculate the rate as haemolysed samples per total samples, monthly, by location and, where policy allows, by collector.
- Find the hot spots. In most hospitals one or two areas, usually the emergency department, produce most of the haemolysis.
- Fix the cause in that area. Line draws, syringe use and needle size are the usual levers.
- Train and observe. A short observed draw with feedback changes practice more than a lecture.
- Compare with peers. The IFCC Working Group on Laboratory Errors and Patient Safety runs a quality indicator programme with published performance specifications. DBO's free anonymous pre-analytical benchmark lets you compare your haemolysis rate with laboratories of the same size and type.
References
- Lippi G, Plebani M, Di Somma S, Cervellin G. Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories. Crit Rev Clin Lab Sci. 2011;48(3):143–153.
- Simundic AM, Bölenius K, Cadamuro J, et al. Joint EFLM-COLABIOCLI Recommendation for venous blood sampling. Clin Chem Lab Med. 2018;56(12):2015–2038. PubMed
- Sciacovelli L, Padoan A, Aita A, Basso D, Plebani M. Quality indicators in laboratory medicine: state-of-the-art, quality specifications and future strategies. Clin Chem Lab Med. 2023;61(4):688–695.
- CLSI. GP41: Collection of Diagnostic Venous Blood Specimens. 7th ed. Clinical and Laboratory Standards Institute; 2017.